Clinical chemistry
-
Case Reports
Transient 5-oxoprolinuria (pyroglutamic aciduria) with systemic acidosis in an adult receiving antibiotic therapy.
5-Oxoprolinuria is a recognized condition with increased urinary excretion of 5-oxoproline and is associated with a variety of inborn metabolic defects involving the series of enzyme-linked reactions known as the gamma-glutamyl cycle. We report the unusual case of a 35-year-old woman who initially presented with staphylococcal pneumonia but went on to develop a transient high anion gap metabolic acidosis. ⋯ We suggest that this patient developed a transient disturbance in the gamma-glutamyl cycle involving the 5-oxoprolinase step, which resulted in accumulation of 5-oxoproline that caused a severe high anion gap metabolic acidosis. The administered antibiotics remain as possible causative agents.
-
Case Reports
Ethylene glycol poisoning: toxicokinetic and analytical factors affecting laboratory diagnosis.
Ethylene glycol poisoning is an important toxicological problem in medical practice because early diagnosis and treatment can prevent considerable morbidity and mortality. When ingested in the form of antifreeze or other automotive products, ethylene glycol results in central nervous system depression, cardiopulmonary compromise, and renal insufficiency. ⋯ Laboratory features of ethylene glycol poisoning include increased anion gap metabolic acidosis, increased osmolal gap, calcium oxalate crystalluria, and detectable ethylene glycol in serum. This Case Conference integrates discussion of the toxicokinetic and analytical variables that affect the laboratory diagnosis of ethylene glycol intoxication.
-
Comparative Study Clinical Trial
Improved detection of minor ischemic myocardial injury with measurement of serum cardiac troponin I.
This study compared the diagnostic accuracy of the measurement of serum cardiac troponin I (cTnI) with creatine kinase (CK) MB mass in patients with minor myocardial injury whose measured total CK activity did not exceed twice the upper reference limit (300 U/L for men; 200 U/L for women). Forty-eight consecutive patients presenting with chest pain and with in-hospital documentation of myocardial injury were enrolled. Electrocardiogram, echocardiogram, and serial serum CK-MB mass, cTnI, and total CK were measured over 36 h after admission. ⋯ The peak biochemical marker index (defined as CK-MB or cTnI divided by its respective upper reference limit) was significantly (P < 0.05) higher for cTnI than for CK-MB from 7 to 36 h. The clinical sensitivity for detection of myocardial injury for cTnI was 100% [95% confidence interval (CI): 87.2% to 100%], compared with 81.8% (CI: 67.3% to 91.8%) for CK-MB. Thus, cTnI was more sensitive than CK-MB mass for detection of myocardial injury in patients with small increases of total CK.