The Knee
-
Comparative Study
Inter- and intra-tester reliability of clinical measurement to determine medio-lateral patellar position using a pachymeter or visual assessment.
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson's Correlation and ICC, for the measurement on the first and second evaluations. ⋯ Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC=0.175; examiner 2 ICC=0.189; examiner 3 ICC=0.155) and pachymeter (examiner 1 ICC=0.214; examiner 2 ICC=0.246; examiner 3 ICC=0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC=[0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks' interval demonstrated an unacceptable reliability.
-
A retrospective study of a consecutive cohort of 109 patients, under the age of 60, who had either a Patellofemoral replacement (PFR), Unicompartmental replacement (UKR) or a Total knee replacement (TKR). They were operated on by two senior surgeons between 2002 and 2006 at the Avon Orthopaedic Centre in Bristol. The aim of this study was to look at the effect of knee replacement on the employment status of this group of patients. ⋯ This is the first study to compare employment status following Patellofemoral, Unicompartmental knee and Total Knee Replacement. TKR and UKR are effective in returning patients under 60 years old to active employment and this is typically 3 months following surgery. Patients who had a PFR did not experience the same benefits in terms of numbers returning to work, time to do so and their subjective opinion as to their ability to cope with normal duties.
-
We evaluated short- and medium-term results of the treatment of articular cartilage defects of the knee with autogenous cylindrical osteochondral grafts (mosaicplasty) in 69 patients (median age 33 years) with symptomatic articular cartilage defects. Data of Lysholm score and visual analogue scale (VAS) of pain (0=no pain; 100=worst possible pain) were collected before the surgery, at 12 months postoperatively and 5 to 9 (median 7) years after the surgery. At the last follow-up the patients were also asked to state their degree of satisfaction with the outcome on a VAS (0=not at all satisfied; 100=completely satisfied), and to answer if they would have undergone the surgery again if necessary (yes or no). ⋯ The mean degree of satisfaction with the outcome was 70 (SD 28), and 61 patients (88%) stated that they would have undergone the surgery again. In conclusion, the mosaicplasty leads to improvement of symptoms and function at short- and medium-term follow-up. A deterioration of the results is observed from 12 months postoperatively to 5-9 years postoperatively.
-
Refined prosthetic designs and surgical techniques for unicompartmental knee arthroplasty have recently been associated with improved outcomes. The purpose of the present study was to evaluate the clinical and radiographic outcomes of the EIUS unicompartmental design, which has an all-polyethylene tibial component, and to compare these outcomes with published reports of other unicompartmental prostheses. Between February 2002 and March 2005, 113 patients (144 knees) underwent a medial unicompartmental knee arthroplasty, all performed by a single surgeon who used the EIUS prosthesis. ⋯ Multiple regression analysis revealed that age, gender, and body mass index were not significantly correlated with success or failure of this design, although nine of the 16 patients who required revision were obese. This prosthesis was associated with higher revision rates than components which utilize metal-backed implants. Further modifications in the design, indications, or technique may be necessary to improve outcomes of this unicompartmental knee arthroplasty system.
-
Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication of unicompartmental knee arthroplasty (UKA). As TPFs usually occur perioperatively, these can be associated with extended sagittal saw cuts during surgery. The aim of the study was to evaluate TPF as a function of extended sagittal saw cuts. ⋯ Extended sagittal saw cuts in UKA weaken the tibial bone structure. Our results show that descendent extended sagittal saw cuts of 10 degrees reduce fracture loads by about 30%. Surgeons should be aware of the potential pitfalls of an extended sagittal saw cut, as this can lead to reduced loading capacity of the tibial plateau and increase the risk of periprosthetic TPF.