Asian cardiovascular & thoracic annals
-
Asian Cardiovasc Thorac Ann · Jul 2017
Comparative StudyEmboli and cognitive state in surgical vs. transcatheter aortic valve replacement.
Background Neurologic complications and neurocognitive impairment due to cerebral emboli are common following heart surgery. This study aimed to compare the number of emboli detected in the middle cerebral artery in open aortic valve replacement, apical and femoral transcatheter aortic valve replacement, and also to test for an association between the number of emboli captured in each procedure and changes in the patient's cognitive state. Methods Forty-four patients were enrolled in the study, 36 of whom were included in the final analyses: 14 underwent open aortic valve replacement, 2 had femoral transcatheter aortic valve replacement, and 10 had apical transcatheter aortic valve replacement. ⋯ Both transcatheter approaches yielded a comparable amount of emboli ( p = 0.798). No significant association was observed between the change in Mini-Mental State Examination score and the mean number of emboli ( r = 0.026; p = 0.907). Conclusions Compared to transcatheter aortic valve replacement, more cerebral emboli are detected during surgical aortic valve replacement; however, this does not appear to adversely affect a patient's cognitive state.