Enfermería intensiva
-
Enfermería intensiva · Apr 2009
[Evaluation of the effectiveness of an in-hospital cardiac alarm system].
⋯ CPR was performed in 90 patients. Average arrival time was 1 minute. Origin was non-cardiac 56%, cardiac 34.4%. Initial rhythm was non-shockable 76.7%, shockable 22.2%. Survival at hospital discharge: 20%. Cerebral Performance Category 1: 89%. Survival after one year 16.7%. Survival: cardiac etiology (P=0.05; OR 0.20; 95% CI 0.06-0.65). Initial rhythm shockable (P=0.0001; OR 0.18; 95% CI 0.05-0.56) CONCLUSIONS: Our CA system is effective. We achieve a survival and cerebral performance categories on hospital discharge that is similar to other studies although the rate of patients with shockable rhythm and cardiac etiology in our series is less than others published.