A system for portable sleep apnea diagnosis using an embedded data capturing module.
Sleep apnea (SA) is a very common disease with serious health consequences, yet is very under-diagnosed, partially because of the high cost and limited accessibility of in-laboratory polysomnography (PSG). The purpose of this work is to introduce a newly developed portable system for the diagnosis of SA at home that is both reliable and easy to use. The system includes personal devices for recording breath sounds and airflow during sleep and diagnostic algorithms to process the recorded data. The data capturing device consists of a wearable face frame with an embedded electronic module featuring a unidirectional microphone, a differential microphone preamplifier, a microcontroller with an onboard differential analogue to digital converter, and a microSD memory card. The device provides continuous data capturing for 8 h. Upon completion of the recording session, the memory card is returned to a location for acoustic analysis. We recruited 49 subjects who used the device independently at home, after which each subject answered a usability questionnaire. Random data samples were selected to measure the signal-to-noise ratio (SNR) as a gauge of hardware functionality. A subset of 11 subjects used the device on 2 different nights and their results were compared to examine diagnostic reproducibility. Independent of those, system's performance was evaluated against PSG in the lab environment in 32 subject. The overall success rate of applying the device in un-attended settings was 94 % and the overall rating for ease-of-use was 'excellent'. Signal examination showed excellent capturing of breath sounds with an average SNR of 31.7 dB. Nine of the 11 (82 %) subjects had equivalent results on both nights, which is consistent with reported inter-night variability. The system showed 96 % correlation with simultaneously performed in-lab PSG. ⋯ Our results suggest excellent usability and performance of this system and provide a strong rationale to further improve it and test its robustness in a larger study.
-
J Clin Monit Comput · Jun 2013
Clinical TrialThe analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.
The photoplethysmography (PPG) signals detected by transesophageal oximetry sensor toward aorta arch (AA), descending aorta (DA), and left ventricle (LV) under the guidance of transesophageal echocardiography (TEE) were investigated, and the effects of filter application on PPG signals were evaluated. Eleven cardiac surgical patients were involved. After anesthesia was induced, the TEE probe with a modified pulse oximetry sensor was inserted. ⋯ The AC amplitude in LV PPG was significant larger than in AA and DA PPG, and both AC/DC and ventilation-induced AC variation in LV PPG were significantly higher than in AA PPG or DA PPG either. There were no significant differences of AC amplitude between filtered and ventilation off PPG signals. The AC amplitudes and AC/DC toward LV are significantly higher than transesophageal oximeter toward AA or DA, and the effect of mechanical ventilation on transesophageal PPG can be obviously reduced by filtering techniques.
-
Heart rate variability (HRV) is a non-invasive method to measure cardiac autonomic function. Impairments in HRV have been proposed as independent risk factor for increased cardiac mortality and morbidity. Cardio protective phenomenon in females has been hypothesized to be due to differential autonomic tone. ⋯ Sympathetic tone predominates and vagal tone diminishes with aging process. Females showed greater vagal tone than male. This differential autonomic tone indicate age, gender related predisposition to cardiovascular disease.
-
J Clin Monit Comput · Jun 2013
Heart rate variability analysis during central hypovolemia using wavelet transformation.
Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorrhaging patients, with the most popular methods involving calculation of the R-R interval signal's power spectral density (PSD) or use of fractal dimensions (FD). However, the latter method poses technical challenges, while the former is best suited to stationary signals rather than the non-stationary R-R interval. ⋯ Results demonstrate that the proposed DWT-based model outperforms individual PSD and FD methods as well as the combination of these two traditional methods at both sample rates of 500 Hz (p value <0.0001) and 125 Hz (p value <0.0001) in detecting the degree of hypovolemia. These findings indicate the potential of the proposed DWT approach in monitoring the physiological changes caused by hemorrhage. The speed and relatively low computational costs in deriving these features may make it particularly suited for implementation in portable devices for remote monitoring.
-
J Clin Monit Comput · Jun 2013
Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring.
Blood pressure monitoring during anesthesia is an American Society of Anesthesiology standard. However, the anesthesia provider sometimes fails to engage the patient monitor to make periodic (generally every 3-5 min) measurements of Non-Invasive Blood Pressure (NIBP), which can lead to extended periods (>5 min) when blood pressure is not monitored. We describe a system to automatically detect such gaps in NIBP measurement and notify clinicians in real-time to initiate measurement. ⋯ The maximum gap encountered before SAM was 64 min, while it was 27 min with SAM notification. Real-time notification using SAM is an effective way to reduce both the number of instances and the duration of inadvertent, extended (>15 min) gaps in blood pressure measurements in the operating room. However, the frequency of gaps <15 min could not be reduced using the current configuration of SAM.