Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2021
Clinical TrialEEG-derived pain threshold index for prediction of postoperative pain in patients undergoing laparoscopic urological surgery: a comparison with surgical pleth index.
Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergoing laparoscopic urological surgery under general anesthesia were enrolled. ⋯ Further analysis indicated that PTI had a best predictive accuracy reflected by highest area under curve (AUC)(0.772, 95% CI: 0.661-0.860)with sensitivity(62.50%) and specificity(90.91%) and a best positive predictive value(83.3%,95% CI: 68.4-98.2%). PTI obtained at the end of surgery, which have better predictive accuracy for postoperative pain than SPI, could differentiate the patients with moderate-to-severe pain from those with mild pain after they awaken from anesthesia. Clinical trial registration Chinese Clinical Trials Registry: ChiCTR1900024789.
-
J Clin Monit Comput · Dec 2021
Randomized Controlled TrialA beat-by-beat cardiovascular index, CARDEAN, to titrate opioid administration in the setting of orthopaedic surgery: a prospective randomized trial.
To determine whether a beat-by-beat cardiovascular index (CARDEAN: cardiovascular depth of analgesia, Alpha-2 Ltd, Lyon, France) reduces the incidence of tachycardia in ASA I-III patients undergoing orthopaedic surgery. A total of 76 patients were prospectively randomized into (1) a control group or (2) the CARDEAN group, in which the nurse anaesthetist was blinded to CARDEAN application. In addition to conventional signs, an external observer instructed the nurse anaesthetist to administer sufentanil 0.1 µg kg-1 when the CARDEAN crossed a threshold (≥ 60). ⋯ Data for 66 patients (27 with known hypertension) were analysed. In the CARDEAN group, (a) the dose of sufentanil was higher (control: 0.46 µg kg-1 100 min-1, CARDEAN: 0.57 µg kg-1 100 min-1, p = 0.016), (b) the incidence rates of tachycardia and untoward events were lower (respectively: - 44%; control: 2.52 events 100 min-1 [1.98-3.22]; CARDEAN: 1.42 [1.03-1.96], p = 0.005, hazard ratio: 0.56; movement, muscular contraction, or coughing: control: 0.74 events 100 min-1 [0.47-1.16]; CARDEAN: 0.31 [0.15-0.62], p = 0.038), and (c) extubation occurred more often in the operating room (control: 76.5%, CARDEAN: 97%, p = 0.016). CARDEAN-titrated opioid administration was associated with a higher dose of sufentanil, a reduction in tachycardia and earlier emergence in ASA I-III patients undergoing major orthopaedic surgery.
-
J Clin Monit Comput · Dec 2021
Randomized Controlled TrialA mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.
To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital between November 2017 and April 2020, and randomly allocated into training (n = 97) and independent validation (n = 41) groups. ⋯ There was no significant difference in baseline demographic characteristics between the training and independent validation groups. The accuracy of the model for predicting ICP was 0.899 in the training cohort (n = 97) and 0.861 in the independent validation cohort (n = 41). We obtained an ICP-predicting model that showed excellent performance in the noninvasive diagnosis of clinically significant communicating hydrocephalus.
-
J Clin Monit Comput · Dec 2021
Anaesthesia and multimodality intraoperative neuromonitoring in carotid endarterectomy. Chronological evolution and effects on intraoperative neurophysiology.
Contingency data was retrospectively collected to evaluate the historical and current ability to provide multimodality intraoperative neurophysiological monitoring during carotid endarterectomy under two conditions: total intravenous anaesthesia (TIVA) and low dose halogenated anaesthesia (SEVO). 229 patients were monitored during carotid endarterectomy procedures under general anaesthesia between 2012 and 2020. 121 Patients were monitored with SEVO at a minimum alveolar concentration less than 0.7 and 108 were monitored using TIVA, according to common anaesthetic practice standards in our hospital across the years. Multimodality IONM was established with electroencephalography, somatosensory evoked potentials and motor evoked potentials. ⋯ When using SEVO, multimodality intraoperative neurophysiological monitoring during carotid endarterectomy could mask or miss a motor isolated change in patients in spite of low dose minimum alveolar concentration and of apparently adequate electroencephalography and somatosensory evoked potentials for monitoring. Given these difficulties, we believe the chronological transfer to TIVA could have improved our ability to establish multimodality intraoperative neurophysiological monitoring during carotid endarterectomy in recent times.
-
J Clin Monit Comput · Dec 2021
Mitochondrial oxygen monitoring with COMET: verification of calibration in man and comparison with vascular occlusion tests in healthy volunteers.
Mitochondria are the primary consumers of oxygen and therefore an important location for oxygen availability and consumption measurement. A technique has been developed for mitochondrial oxygen tension (mitoPO2) measurement, incorporated in the COMET. In contrast to most textbooks, relatively high average mitoPO2 values have been reported. ⋯ The kinetics from this decline are used to mitochondrial oxygen consumption (mitoVO2). This study validates the calibration of the COMET device in humans. For mitoVO2 measurements not only blood flow cessation but application of local pressure is of great importance to clear the measurement site of oxygen-carrying erythrocytes.