Observational StudyDeviations in continuously monitored electrodermal activity before severe clinical complications: a clinical prospective observational explorative cohort study.
Monitoring of high-risk patients in hospital wards is crucial in identifying and preventing clinical deterioration. Sympathetic nervous system activity measured continuously and non-invasively by Electrodermal activity (EDA) may relate to complications, but the clinical use remains untested. The aim of this study was to explore associations between deviations of EDA and subsequent serious adverse events (SAE). ⋯ We included 714 patients and found a total of 192 statistically significant associations between EDA-derived features and clinical outcomes. 79% of these associations were EDA-derived features of absolute and relative increases in EDA and 14% were EDA-derived features with normalized EDA above a threshold. The highest F1-scores for primary outcome with the four time-perspectives were 20.7-32.8%, with precision ranging 34.9-38.6%, recall 14.7-29.4%, and specificity 83.1-91.4%. We identified statistically significant associations between specific deviations of EDA and subsequent SAE, and patterns of EDA may be developed to be considered indicators of upcoming clinical deterioration in high-risk patients.
-
J Clin Monit Comput · Dec 2023
Case ReportsRecording of a left ventricle assist device electrical current with a neurally adjusted ventilation assist (NAVA) catheter: a small case series.
Neurally Adjusted Ventilatory Assist (NAVA) is an adaptive ventilation mode that recognizes electromyographic diaphragmatic activation as a sensory input to control the ventilator. NAVA may be of interest in prolonged mechanical ventilation and weaning, as it provides effort-adapted support, improves patient-ventilator synchronization, and allows additional monitoring of neuromuscular function and drive. Ventricular assist devices (VAD), especially for the left ventricle (LVAD), are increasingly entering clinical practice, and intensivists are faced with distinct challenges such as the interaction between the system and other measures of organ support. ⋯ An implanted LVAD can render the NAVA signal unusable for ventilatory support because the LVAD signal can interfere with the recording of electromyographic activation of the diaphragm. Therefore, patients with implanted LVAD may need other modes of ventilation than NAVA for advanced weaning strategies.
-
J Clin Monit Comput · Dec 2023
Review Meta AnalysisConfirming identification of the epidural space: a systematic review of electric stimulation, pressure waveform analysis, and ultrasound and a meta-analysis of diagnostic accuracy in acute pain.
To review the use of epidural electric stimulation test, pressure waveform analysis, and ultrasound assessment of injection as bedside methods for confirming identification of the epidural space in adults with acute pain, the PubMed database was searched for relevant reports between May and August 2022. Studies reporting diagnostic accuracy with conventional Touhy needles and epidural catheters were further selected for meta-analysis. Sensitivity and specificity were estimated using univariate logistic regression for electric stimulation and pressure analysis, and pooling of similar studies for ultrasound. ⋯ Risk of bias was significant and accuracy estimates must be interpreted with caution. Electric stimulation and pressure waveform analysis seem clinically useful, although they must be interpreted cautiously. In the future, clinical trials in patients with difficult anatomy will likely be most useful. Ultrasound requires further investigation.
-
J Clin Monit Comput · Dec 2023
Randomized Controlled TrialComparative analysis of signal accuracy of three SpO2 monitors during motion and low perfusion conditions.
To compare pulse oximetry performance during simulated conditions of motion and low perfusion in three commercially available devices: GE HealthCare CARESCAPE ONE TruSignal SpO2 Parameter, Masimo RADICAL-7 and Medtronic Nellcor PM1000N. After IRB approval, 28 healthy adult volunteers were randomly assigned to the motion group (N = 14) or low perfusion (N = 14) group. Pulse oximeters were placed on the test and control hands using random assignment of digits 2-5. ⋯ SpO2 measurement accuracy degraded for all three devices during motion as compared to non-motion. Accuracy also degraded during normal to low, very low, or ultra low perfusion and was more pronounced compared to the changes observed during simulated motion. While some statistically significant differences in individual measurements were found, the clinical relevance of these differences requires further study.
-
J Clin Monit Comput · Dec 2023
A technique to measure tidal volume during noninvasive respiratory support by continuous-flow helmet CPAP.
The coronavirus disease 2019 (COVID-19) pandemic has promoted the use of helmet continuous positive airway pressure (CPAP) for noninvasive respiratory support in hypoxic respiratory failure patients, despite the lack of tidal volume monitoring. We evaluated a novel technique designed to measure tidal volume during noninvasive continuous-flow helmet CPAP. ⋯ Tidal volume measurement is feasible and accurate during bench continuous-flow helmet CPAP therapy by the analysis of the outflow signal, provided that helmet inflow is adequate to match the patient's inspiratory efforts. Insufficient inflow resulted in tidal volume underestimation. In vivo data are needed to confirm these findings.