Perioperative medicine is changing, and its goals are expanding. More and more attention is paid to the surgical experience and the patient's quality of life. ⋯ However, creating perioperative programs capable of integrating traditional perioperative data with these scales is not easy. New technologies, particularly artificial intelligence, thanks to their ability to recognise, interpret, process or simulate human feelings, emotions and moods, could provide the necessary tools to combine all perioperative aspects, placing the patients and their needs at the centre of the process.
-
J Clin Monit Comput · Dec 2023
Review Meta AnalysisConfirming identification of the epidural space: a systematic review of electric stimulation, pressure waveform analysis, and ultrasound and a meta-analysis of diagnostic accuracy in acute pain.
To review the use of epidural electric stimulation test, pressure waveform analysis, and ultrasound assessment of injection as bedside methods for confirming identification of the epidural space in adults with acute pain, the PubMed database was searched for relevant reports between May and August 2022. Studies reporting diagnostic accuracy with conventional Touhy needles and epidural catheters were further selected for meta-analysis. Sensitivity and specificity were estimated using univariate logistic regression for electric stimulation and pressure analysis, and pooling of similar studies for ultrasound. ⋯ Risk of bias was significant and accuracy estimates must be interpreted with caution. Electric stimulation and pressure waveform analysis seem clinically useful, although they must be interpreted cautiously. In the future, clinical trials in patients with difficult anatomy will likely be most useful. Ultrasound requires further investigation.
-
J Clin Monit Comput · Dec 2023
Randomized Controlled TrialComparative analysis of signal accuracy of three SpO2 monitors during motion and low perfusion conditions.
To compare pulse oximetry performance during simulated conditions of motion and low perfusion in three commercially available devices: GE HealthCare CARESCAPE ONE TruSignal SpO2 Parameter, Masimo RADICAL-7 and Medtronic Nellcor PM1000N. After IRB approval, 28 healthy adult volunteers were randomly assigned to the motion group (N = 14) or low perfusion (N = 14) group. Pulse oximeters were placed on the test and control hands using random assignment of digits 2-5. ⋯ SpO2 measurement accuracy degraded for all three devices during motion as compared to non-motion. Accuracy also degraded during normal to low, very low, or ultra low perfusion and was more pronounced compared to the changes observed during simulated motion. While some statistically significant differences in individual measurements were found, the clinical relevance of these differences requires further study.
-
J Clin Monit Comput · Dec 2023
A technique to measure tidal volume during noninvasive respiratory support by continuous-flow helmet CPAP.
The coronavirus disease 2019 (COVID-19) pandemic has promoted the use of helmet continuous positive airway pressure (CPAP) for noninvasive respiratory support in hypoxic respiratory failure patients, despite the lack of tidal volume monitoring. We evaluated a novel technique designed to measure tidal volume during noninvasive continuous-flow helmet CPAP. ⋯ Tidal volume measurement is feasible and accurate during bench continuous-flow helmet CPAP therapy by the analysis of the outflow signal, provided that helmet inflow is adequate to match the patient's inspiratory efforts. Insufficient inflow resulted in tidal volume underestimation. In vivo data are needed to confirm these findings.