Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2017
Design and α-testing of an electronic rounding tool (CERTAINp) to improve process of care in pediatric intensive care unit.
Increasing process complexity in the pediatric intensive care unit (PICU) can lead to information overload resulting in missing pertinent information and potential errors during morning rounds. An efficient model using a novel electronic rounding tool was designed as part of a broader critical care decision support system-checklist for early recognition and treatment of acute illness and injury in pediatrics (CERTAINp). We aimed to evaluate its impact on improving the process of care during rounding. ⋯ Rounding time (mean ± SD) increased by 2 min/patient (8.0 ± 5.8 min pre-intervention vs. 9.9 ± 5.7 min post-intervention, p = 0.002). Staff reported improved perception of all aspects of rounding. Utilization of the CERTAINp rounding tool led to perfect compliance to the discussion of best practice guidelines; had minimal impact on rounding time and improved PICU staff satisfaction.
-
J Clin Monit Comput · Dec 2017
Observational StudyEvaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test.
An increasing number of NIRS devices are used to provide measurements of peripheral tissue oxygen saturation (StO2). The aim of the present study is to test the hypothesis that despite technological differences between devices, similar trend values will be obtained during a vascular occlusion test. The devices compared are NIRO-200NX, which measures StO2 and oxyhemoglobin by spatially resolved spectroscopy and the Beer-Lambert law, respectively, and INVOS 5100C and Foresight Elite, which both measure StO2 with the Beer-Lambert law, enhanced with the spatial resolution technique. ⋯ Oxyhemoglobin measured with NIRO responded faster than the other NIRS technologies to changes in peripheral tissue oxygenation (20 vs. 27-40 s, p ≤ 0.01). When comparing INVOS with Foresight, oxygenation changes were prompter (upslope 311 [92-523]%/min vs. 114[65-199]%/min, p ≤ 0.01) and more pronounced (minimum value 36 [21-48] vs. 45 [40-51]%, p ≤ 0.01) with INVOS. Significant differences in tissue oxygen saturation measurements were observed, both within the same device as between different devices using the same measurement technology.
-
J Clin Monit Comput · Dec 2017
Measuring core temperature using the proprietary application and thermo-smartphone adapter.
Fast and accurate measurement of core body temperature is crucial for accidental hypothermia treatment. We have developed a novel light and small adapter to the headset jack of a mobile phone based on Android. It has been applied to measure temperature and set up automatic notifications (e.g. ⋯ Inter-method difference of ≤0.5 °C was found for 98.5% for esophageal catheter and 100% for tympanic catheter measurements, with concordance correlation coefficient of 0.99 for both. The readings were almost completely repeatable with water bath measurements (difference of ≤0.5 °C in 10 °C: 100% for both catheters; in 25 °C: 99% for esophageal catheter and 100% tympanic catheter; in 42 °C: 100% for both catheters). This lightweight adapter attached to smartphone and standard disposable probes is a promising tool to be applied on-site for temperature measurement in patients at risk of hypothermia.
-
J Clin Monit Comput · Dec 2017
Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.
Radial artery applanation tonometry (RAAT) has been developed and utilized for continuous arterial pressure monitoring. However, evidence is lacking to clinically verify the RAAT technology and identify appropriate patient groups before routine clinical use. This study aims to evaluate the RAAT technology by comparing systolic blood pressure (SBP), mean blood pressure (MBP) and diastolic blood pressure (DBP) values in patients undergoing colon carcinoma surgery. ⋯ A highly selected patient collective undergoing colon carcinoma surgery was studied. BP measurements obtained via the TL-300 had clinically acceptable agreement with that acquired invasively using an arterial catheter. For use in clinical routine, it is necessary to take measures for improvement regarding movement artifacts and dilution of noise. A large sample size of patients under various conditions is also needed to further evaluate the RAAT technology before clinically routine use.
-
J Clin Monit Comput · Dec 2017
Sound level analysis in endotracheal tube obstruction in spontaneous breathing and mechanical ventilation-an animal model study.
Endotracheal tube (ETT) obstruction, either complete or partial, is a serious life threatening complication in intubated patients. Therefore, implementing a practical method to diagnose this condition is vital. Alteration in respiratory sound signals caused by ETT occlusion can be used for early detection of obstruction. ⋯ In addition, this change in sound level was not related to the location of obstruction. The decrease in sound intensity changes can be used to detect ETT obstruction. However, further studies are needed for clinical application.