IEEE transactions on ultrasonics, ferroelectrics, and frequency control
-
IEEE Trans Ultrason Ferroelectr Freq Control · Apr 2015
LetterNoninvasive arterial blood pressure waveform monitoring using two- element ultrasound system.
This work details noninvasive arterial blood pressure (ABP) waveform estimation based on an arterial vessel cross-sectional area measurement combined with an elasticity measurement of the vessel, represented by pulse wave velocity (PWV), using a two-element ultrasound system. The overall ABP waveform estimation is validated in a custom-designed experimental setup mimicking the heart and an arterial vessel segment with two single element transducers, assuming a constant hemodynamic system. ⋯ The distension waveform obtained from a complex cross-correlation model estimator (C3M) reliably traces small pressure changes reflected by the diameter change. The excellent agreement of an estimated pressure waveform to the reference pressure waveform suggests the promising potential of a readily available, inexpensive, and portable ABP waveform monitoring device.
-
IEEE Trans Ultrason Ferroelectr Freq Control · Feb 2015
Two-dimensional shear-wave elastography on conventional ultrasound scanners with time-aligned sequential tracking (TAST) and comb-push ultrasound shear elastography (CUSE).
Two-dimensional shear-wave elastography presents 2-D quantitative shear elasticity maps of tissue, which are clinically useful for both focal lesion detection and diffuse disease diagnosis. Realization of 2-D shear-wave elastography on conventional ultrasound scanners, however, is challenging because of the low tracking pulse-repetition-frequency (PRF) of these systems. Although some clinical and research platforms support software beamforming and plane-wave imaging with high PRF, the majority of current clinical ultrasound systems do not have the software beamforming capability, which presents a critical challenge for translating the 2-D shear-wave elastography technique from laboratory to clinical scanners. ⋯ An inclusion phantom study showed that the conventional ultrasound scanner had comparable performance to a state-of-the-art shear-wave imaging system in terms of bias and precision in measuring different sized inclusions. Finally, in vivo case analysis of a breast with a malignant mass, and a liver from a healthy subject demonstrated the feasibility of using the conventional ultrasound scanner for in vivo 2-D shear-wave elastography. These promising results indicate that the proposed technique can enable the implementation of 2-D shear-wave elastography on conventional ultrasound scanners and potentially facilitate wider clinical applications with shear-wave elastography.
-
IEEE Trans Ultrason Ferroelectr Freq Control · Feb 2015
Ultrasound-induced heart rate decrease: role of the vagus nerve.
The goal of this study is to investigate the role of the vagus nerve (VN) in the ultrasound (US)-induced negative chronotropic effect (deceased heart rate). One of the functions of the VN is to mediate lowering of the heart rate. A previous study showed a decrease of ~20% in the heart rate but the mechanism of the effect was not investigated. ⋯ The vagotomy group showed similar ultrasound-induced cardiac effects compared with the non-vagotomy group, suggesting that the vagus nerve is not influenced by the ultrasound exposure procedures. The US application caused a negative chronotropic effect of the rat heart without affecting the hemodynamic conditions. The results at this point are suggestive for an alternative cardiac pacing capability.
-
IEEE Trans Ultrason Ferroelectr Freq Control · Jan 2014
An integrated system for the segmentation of atherosclerotic carotid plaque ultrasound video.
The robust border identification of atherosclerotic carotid plaque, the corresponding degree of stenosis of the common carotid artery (CCA), and also the characteristics of the arterial wall, including plaque size, composition, and elasticity, have significant clinical relevance for the assessment of future cardiovascular events. To facilitate the follow-up and analysis of the carotid stenosis in serial clinical investigations, we propose and evaluate an integrated system for the segmentation of atherosclerotic carotid plaque in ultrasound videos of the CCA based on video frame normalization, speckle reduction filtering, M-mode state-based identification, parametric active contours, and snake segmentation. Initially, the cardiac cycle in each video is identified and the video M-mode is generated, thus identifying systolic and diastolic states. ⋯ The segmentation results were very satisfactory, according to the expert objective evaluation, for the two different methods investigated, with true-negative fractions (TNF-specificity) of 83.7 ± 7.6% and 84.3 ± 7.5%; true-positive fractions (TPF-sensitivity) of 85.42 ± 8.1% and 86.1 ± 8.0%; and between the ground truth and the proposed segmentation method, kappa indices (KI) of 84.6% and 85.3% and overlap indices of 74.7% and 75.4%. The segmentation contours were also used to compute the cardiac state identification and radial, longitudinal, and shear strain indices for the CCA wall and plaque between the asymptomatic and symptomatic groups were investigated. The results of this study show that the integrated system investigated in this study can be successfully used for the automated video segmentation of the CCA plaque in ultrasound videos.
-
IEEE Trans Ultrason Ferroelectr Freq Control · Jul 2012
A single FPGA-based portable ultrasound imaging system for point-of-care applications.
We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. ⋯ The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.