This study investigated the appropriate tourniquet pressure (TP) and duration of tourniquet application for venipuncture by calculating the venous cross-section (VCS) area on ultrasonography. Twenty healthy volunteers without cardiovascular risk factors were enrolled in this study. A target vein (either a cephalic or median cubital vein) was selected on ultrasonography. ⋯ After that, the VCS area did not increase remarkably. The VCS area increased with TP strength up to 80 mmHg, but the VCS area at TP 100 mmHg decreased to less than that at TP 40 mmHg. Based on these results, we recommend a tourniquet pressure of 60 mmHg, and duration of tourniquet application is 30 to 60 sec for venipuncture.
-
To quantify gait bradykinesia during daily activity in patients with Parkinson's disease (PD), we measured movement-induced accelerations over more than 24h in 50 patients with PD and 17 age-matched normal controls, using a new device, the portable gait rhythmogram. Acceleration values induced by various movements, averaged each 10 min, exhibited a gamma distribution. The mean value of the distribution curve was used as an index of the "amount of overall movement per 24h". ⋯ During hypokinesia, the gait cycle became either faster or slower. A number of patients with marked akinesia/bradykinesia showed a reduced and narrow range of gait acceleration, i.e., a range of floor reaction forces. The results suggest that assessment of the combination of changes in gait cycle and gait acceleration can quantitatively define the severity of gait bradykinesia.