The British journal of radiology
-
Pneumothorax post CT-guided lung biopsy: a comparison between detection on chest radiographs and CT.
Pneumothorax is reported to be a more common complication of lung biopsy performed under computed tomography (CT) than under fluoroscopic guidance. This may simply reflect the greater sensitivity of CT over chest radiographs (CXRs) in the detection of small pneumothoraces. This study aimed to determine the incidence of pneumothorax detected by CXR and by CT after CT-guided biopsy of non-pleurally based pulmonary masses, and to compare these incidences with previous reports in the literature of pneumothorax incidence post fluoroscopic biopsy. 88 consecutive CT-guided lung biopsies of masses not abutting the pleural surface were included. ⋯ None required tube drainage. Of the patients in whom CT demonstrated a pneumothorax, the average depth of this was significantly greater for those in whom CXR also detected a pneumothorax compared with those in whom CXR was negative (7.3 mm versus 3.4 mm, p < 0.05). The incidence of pneumothorax detected on CXR post CT-guided biopsy is similar to the reported incidence post fluoroscopic biopsy.