The British journal of radiology
-
Comparative Study
Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques.
The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b = 0, b = 20, b = 300, b = 800 s mm(-2)) and single-shot T2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with special interest in small (<10 mm) lesions. Twenty-four patients underwent routine MRI. The five sequences were compared qualitatively for image quality, lesion conspicuity and artefacts. ⋯ T2W TSE was found to be the best protocol (p<0.05) for the identification of biliary cysts and SE-EPI DWI (b = 20 s mm(-2)) for haemangiomas and metastases. The lesion-to-liver CNRs were highest on T2W TSE for biliary cysts and on SE-EPI diffusion-weighted imaging (DWI) for haemangiomas and metastases (p<0.05). This study shows the potential of SS SE-EPI DWI (especially with a b-value of 20 s mm(-2)) as a promising technique for detecting small (<10 mm) focal liver lesions.