To determine the number of imaging examinations, radiation dose and the time to complete trauma-related imaging in multiple trauma patients before and after introduction of whole-body CT (WBCT) into early trauma care. ⋯ WBCT in trauma patients is associated with a high radiation dose of 29.5 mSv.
-
Evaluation of absolute radiation exposure values for interventional radiologists (IRs) using a multiaxis interventional flat-panel C-arm cone beam CT (CBCT) system with three-dimensional laser guidance for biopsy in a triple-modality, abdominal phantom. ⋯ The results indicate that using modern navigation tools and CBCT can be accompanied with a relative high radiation dose for the IRs since detector angulation can make the use of proper lead shielding difficult.
-
In radiotherapy treatment, planning target volume and organs at risk are contoured on kilovoltage CT (kVCT) images. Unlike MR images, kVCT does not provide precise information on target volume extension. Since neither kVCT nor MRI may be suitable for contouring in patients with ferrous hip prostheses, this study evaluated whether megavoltage CT (MVCT) reduced interobserver variability. ⋯ We recommend the fine modality MVCT for contouring hip prostheses patients.
-
With increased signal to noise ratios, 7.0-T MRI has the potential to contribute unique information regarding anatomy and pathophysiology of a disease. However, concerns for the safety of subjects with metallic medical implants have hindered advancement in this field. The purpose of the present research was to evaluate the MRI safety for 39 commonly used medical implants at 7.0 T. ⋯ Lack of MRI testing for common metallic medical implants limits the translational potential of 7.0-T MRI. For safety reasons, patients with metallic implants are not allowed to undergo a 7.0-T MRI scan, precluding part of the population that can benefit from the detailed resolution of ultra-high-field MRIs. This investigation provides necessary MRI testing of common medical implants at 7.0 T.
-
Placental adhesive disorder (PAD) is a serious pregnancy complication that occurs when the chorionic villi invade the myometrium. Placenta praevia and prior caesarean section are the two important risk factors. ⋯ Imaging findings that are helpful for the diagnosis include dark intraplacental bands, direct invasion of adjacent structures by placental tissue, interruption of normal trilayered myometrium and uterine bulging. Clinicians should be aware of imaging features of PAD to facilitate optimal patient management.