Respiratory care
-
Comparative Study
Economics of Home Monitoring for Apnea in Late Preterm Infants.
Apnea of prematurity affects a small proportion but large absolute number of late preterm infants, with out-patient management variably utilized despite relative clinical equipoise and potential for improved cost-effectiveness. ⋯ Out-patient management of discharge-delaying ABD events in a late preterm and term population was a cost-effective alternative to prolonged in-patient observation.
-
Comparative Study
A Comparison of Different Techniques for Interfacing Capnography With Adult and Pediatric Supplemental Oxygen Masks.
Accurately measuring the partial pressure of end-tidal CO2 (PETCO2 ) in non-intubated patients is problematic due to dilution of expired CO2 at high O2 flows and mask designs that may either cause CO2 rebreathing or inadequately capture expired CO2. We evaluated the performance of 2 capnographic O2 masks (Cap-ONE and OxyMask) against a clinically expedient method using a standard O2 mask with a flow-directed nasal cannula used for capnography (CapnoLine) in a spontaneous breathing model of an adult and child under conditions of normal ventilation, hypoventilation, and hyperventilation. ⋯ Both of the specially designed O2 capnography masks provided reasonably stable PETCO2 without significant CO2 rebreathing at the commonly used O2 flows. Because of their open design, PETCO2 measured at high O2 flows may produce artificially lower readings that may not reflect arterial CO2 levels compared with lower O2 flows.
-
Capnometry detects hypoventilation earlier than pulse oximetry while supplemental oxygen is being administered. We compared the end-tidal CO2 (PETCO2 ) measured using a newly developed oxygen nasal cannula with a CO2-sampling port and the PaCO2 in extubated subjects after abdominal surgery. We also investigated whether the difference between PaCO2 and PETCO2 is affected by resting, by spontaneous breathing with the mouth consciously closed, and by deep breathing with the mouth closed. ⋯ PETCO2 measurements under deep breathing with mouth closed with a capnometry-type oxygen cannula improved the prediction of the absolute value of PaCO2 in extubated post-abdominal surgical subjects without respiratory dysfunction.
-
Partial pressure of end-tidal carbon dioxide (PETCO2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring PETCO2 in children without a tracheal tube is challenging. To improve PETCO2 measurement accuracy in a commercially available mask with a mainstream CO2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. ⋯ PETCO2 measurement by a redesigned open-system face mask with a mainstream CO2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children.
-
During both nasal noninvasive ventilation (NIV) and invasive ventilation of neonates, the presence of air leaks causes triggering and cycling asynchrony. ⋯ The ability of leak compensation to prevent asynchronous breathing varied widely between ventilators and lung mechanics. The PB980 and V500 were the only two ventilators to acclimate to all leak scenarios in invasive ventilation, and PB980 was the only ventilator to acclimate to all leak scenarios in NIV.