Archives des maladies du coeur et des vaisseaux
-
Arch Mal Coeur Vaiss · Feb 2004
[Value of the association of D-dimer measurement and the evaluation of clinical probability in a non-invasive diagnostic strategy of pulmonary embolism].
New diagnostic tools in suspected pulmonary embolism complete the classical diagnostic strategy of pulmonary scintigraphy and pulmonary angiography to limit the indications of these two invasive investigations. In a prospective series of 204 consecutive patients with suspected pulmonary embolism the association of D-dimer measurement and clinical probability was assessed for the exclusion of the diagnosis of pulmonary embolism. The D-DI Liatest is a new generation, unitary, rapid and quantitative latex test with a comparative diagnostic performance to that of the reference ELISA test, and well adapted to emergency situations. ⋯ The prevalence of pulmonary embolism was 42.6% and the absence of anticoagulation in patients considered not to have pulmonary embolism was associated with a thrombo-embolic incidence of 0.9% at 3 months. Fifty-six patients had D-dimer concentrations equal or inferior to the threshold of 500 microg/L; the sensitivity was 99% and the specificity 47% with a negative predictive value of 98% to 100% in cases with a low clinical probability. D-dimer measurement is reliable and has a high cost-benefit value in ambulatory patients with suspected of pulmonary embolism and is even more valuable when the clinical probability of this diagnosis is low.