Laboratory animals
-
Randomized Controlled Trial
Airway management using a supraglottic airway device without endotracheal intubation for positive ventilation of anaesthetized rats.
Endotracheal intubation is often necessary for positive pressure ventilation of rats during open thoracic surgery. Since endotracheal intubation in rats is technically difficult and is associated with numerous complications, many techniques using various devices have been described in the scientific literature. In this study, we compared the effectiveness of airway management of a home-made supraglottic airway device (SAD), which is cheap to fabricate and easy to place with that of an endotracheal intubation tube in enflurane-anaesthetized rats. ⋯ Proper placement of the SAD was confirmed by observing chest wall movements that coincided with the operation of the mechanical ventilator. No complications and adverse events were encountered in the rats in which the SAD was placed, during SAD placement and immediate removal, during their mechanical ventilation through the SAD, and one week after SAD removal. From the results of blood gas analyses, we conclude that anaesthetized rats can be successfully ventilated using an SAD for open thoracic surgery.
-
In biomedical research the pig is widely used as an animal model for experimental surgery. Feasible monitoring tools during anaesthesia are pivotal for successful and reliable research outcome. Blood lactate values are a monitoring tool and prognostic indicator during surgery both in humans and animals. ⋯ Considering genetic background, Rheinhybrid/Pietrain pigs (n = 51; median, 1.4 mmol/L; IQR, 1) had significantly higher blood lactate levels compared with Landrace/Pietrain crossbred animals (n = 73; median, 1.1 mmol/L; IQR, 1; P < 0.05). Body weight had no significant effect on blood lactate levels within the evaluated range. This report can benefit research projects monitoring blood lactate values in farm pigs during experimental surgery.
-
Randomized Controlled Trial
Intraperitoneal medetomidine: a novel analgesic strategy for postoperative pain management in pregnant sheep.
The absorption of medetomidine released by continuous infusion from an osmotic pump in the abdominal cavity was studied in pregnant sheep during the 24 h postoperative period. Additionally pain and sedation was assessed. Eleven sheep were studied: six were treated with a medetomidine loaded osmotic pump delivering 10 µL/h (3 µg/kg/h medetomidine); and five with a saline loaded osmotic pump (control). ⋯ Sheep receiving medetomidine analgesia had significantly lower pain scores at 10 h than controls. Four control sheep required rescue analgesia, compared with 0 in the treatment group. Delivery of 3 µg/kg/h medetomidine by an intraperitoneal osmotic pump to pregnant sheep in the 24 h postoperative period provides adequate plasma concentrations of medetomidine for analgesia without sedation.
-
Hyperpolarized noble gas (HNG) magnetic resonance imaging (MRI) has been shown to be useful for studying rodent models of lung disease. Image quality can be substantially degraded by signal loss from molecular oxygen entering the airway, requiring invasive surgery to ensure a good seal between the endotracheal (ET) tube and trachea. A modified Foley catheter having an inflatable cuff near the tip provides a novel approach for ensuring image quality for HNG MRI, thereby enabling longitudinal studies and reducing animal numbers. ⋯ The Foley catheter resulted in minimal leak rates (-0.20 (0.03) versus -0.16 (0.05) cmH(2)O/s), and were shown to be well below upper-limit leak rates of -0.5 and -0.7 cmH(2)O/s. Tracheal samples from rats in a separate Foley group (not mechanically ventilated) showed superficial damage six days postextubation (grade = 0). (3)He imaging performed using the Foley showed good image quality. Though some technical issues remain to be solved, a modified Foley catheter used as an ET tube offers the potential to enable longitudinal studies in rodents and reduce animal numbers.