The indirect calorimetry in very low birth weight preterm infants: An easier and reliable procedure.
- Michela Perrone, Domenica Mallardi, Chiara Tabasso, Beatrice Bracco, Camilla Menis, Pasqua Piemontese, Orsola Amato, Nadia Liotto, Paola Roggero, and Fabio Mosca.
- Neonatal Intensive Care Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. Electronic address: michela.perrone@policlinico.mi.it.
- Nutrition. 2021 Jun 1; 86: 111180.
ObjectivesPreterm infants are at increased risk of developing extrauterine growth restriction, which is associated with worse health outcomes. The energy needs are not well known, as the measurement of resting energy expenditure (REE) using indirect calorimetry has critical issues when applied to infants. One of the main issues is the time required to obtain reliable data owing to the difficulty in keeping infants quiet during the entire examination. Thus, the aim of this study was to define the minimum duration of calorimetry to obtain reliable data.MethodsThe volume of oxygen consumption (VO2) and the volume of carbon dioxide production (VCO2) were recorded for a mean duration of 90 consecutive minutes. REE was calculated using a neonatal prototype calculator. We extracted data regarding VO2, VCO2, and REE at 10(T1), 20(T2), 30(T3), 40(T4), and 50(T5) minutes of steady state and compared these data to those of entire steady state period.ResultsTwenty-six very low birth weight preterm infants were evaluated at 36.58 ± 0.99 wk corrected age. Infants were appropriate for gestational age and clinically stable without comorbidities. There were no significant differences between mean VO2 and REE at T1 (8.26 ± 1.45 mL/kg to 57.80 ± 10.51 kcal/kg), T2 (8.15 ± 1.41 mL/kg to 56.87 ± 10.05 kcal/kg), T3 (8.04 ± 1.41 mL/kg to 56.32 ± 9.73 kcal/kg), T4 (8.05 ± 1.41 mL/kg to 56.07 ± 10.28 kcal/kg), and T5 (8.06 ± 1.55 mL/kg to 57.17 ± 11.62 kcal/kg), respectively, compared to steady state (8.13 ± 1.33 mL/kg to 56.77 ± 9.34 kcal/kg). The median values of VCO2 were significantly different only when T1 data were compared with other time slots (7.02 ± 1.02 mL/kg at steady state; 7.26 ± 1.23 mL/kg at T1; 7.13 ± 1.20 mL/kg at T2; 7.02 ± 1.19 mL/kg at T3; 6.85 ± 1.16 mL/kg at T4; 6.91 ± 1.24 mL/kg at T5).ConclusionTwenty consecutive minutes in steady state condition are sufficient to obtain reliable data on REE in stable, very low birth weight infants.Copyright © 2021 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.