• Clin Lab · Apr 2019

    Comparative Study

    Comparison of Three Immunoassays Systems for Determining Serum Estradiol.

    • Hongyu Zhang, Yiyong Huang, and Ka Liang.
    • Clin Lab. 2019 Apr 1; 65 (4).

    BackgroundEstrogens are responsible for the development of the secondary female gender characteristics. Serum estradiol concentration measurements depend widely on automated immunoassay systems such as the Architect i2000SR, Cobas e601, and UniCel DxI 800. Here, we compare the performance of three automated immunoassay systems and investigate the correlation of serum estradiol levels.MethodsThe precision of the three automated immunoassay systems were evaluated by the Bio-Rad Laboratories Quality Control products according to the EP15-A2 document. Measurements of 81 serum samples from routine clinical specimens were completed on the Architect i2000SR, Cobas e601, and UniCel DxI 800 on the same day in our laboratory. Method comparison was performed using Bland-Altman and Passing-Bablok analyses. The correlation between the three detection systems was analyzed using the concordance correlation coefficient r.ResultsWith the Bio-Rad Laboratories Quality Control products, we clearly demonstrated that the total inaccuracy of the Architect i2000SR detection systems is in the range of 1.61 - 5.64, the Roche Cobas e601 inaccuracy is in the range of 1.88 - 6.56, and the inaccuracy of the UniCel DxI 800 is in the range of 4.69 - 8.33. A Bland-Altman plot showed that serum estradiol concentrations determined by the Architect i2000SR were about 0.69 times those of the Roche Cobas e601, the Architect i2000SR concentrations were about 0.65 times those of the UniCel DxI 800, and the Roche Cobas e601 concentrations were about 0.96 times those of the UniCel DxI 800. The correlation coefficient r was 0.9936, 0.9857, and 0.9774 for the Architect i2000SR versus the Roche Cobas e601, the Architect i2000SR versus the UniCel DxI 800, and the Roche Cobas e601 versus the UniCel DxI 800, respectively.ConclusionsThe Architect i2000SR system had better precision. The three detection systems have good correlation with each other, but there is a large gap between the results of their detection of estradiol.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.