AJR Am J Roentgenol · Jan 2008
Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding.
- Courtney Coursey, Donald P Frush, Terry Yoshizumi, Greta Toncheva, Giao Nguyen, and S Bruce Greenberg.
- Division of Pediatric Radiology, Department of Radiology, Box 3808, Duke University Medical Center, Durham, NC 27710, USA.
- AJR Am J Roentgenol. 2008 Jan 1; 190 (1): W54-61.
ObjectiveThe purpose of our study was to assess the effect on radiation dose and image noise during pediatric chest 16-MDCT using automatic tube current modulation and bismuth breast shields.Materials And MethodsAge-based chest 16-MDCT was performed on an anthropomorphic phantom representing a 5-year-old child. Two scans were obtained in each of four sequences: first, without a shield; second, with a 2-ply bismuth shield; third, using automatic tube current modulation with a scout image obtained after placement of the shield; and fourth, using automatic tube current modulation with a scout image obtained before placement of the shield. Metal oxide semiconductor field effect transistor technology was used to measure the radiation dose in 20 organ locations. Effective dose was estimated using the console dose-length product. Noise was measured by recording the SD of Hounsfield units in identical regions of interest.ResultsThe bismuth breast shield reduced the dose to the breast by 26%. Shielding and automatic tube current modulation reduced the breast dose by 52%. Multiple organ doses were lowest when the shield was placed after the scout radiograph had been obtained. When the shield was placed after the scout image was obtained, the mean noise in the range of shielding increased from 11.4 to 13.1 H (superior mediastinum) and from 10.0 to 12.8 H (heart) (p < 0.01). Increased noise, however, was near the target noise index (measured in SD of Hounsfield units) of 12.0 H (SD). Using automatic tube current modulation, the effective dose was reduced by 35% when the shield was placed after the scout and by 20% when the shield was present in the scout.ConclusionThe greatest dose reduction is achieved by placing the shield after obtaining the scout image to avoid Auto mA compensation due to density of shield. With this technique, image noise increased but remained close to the target noise index.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.