-
Comparative Study
Spatial location and strength of BOLD activation in high-spatial-resolution fMRI of the motor cortex: a comparison of spin echo and gradient echo fMRI at 7 T.
- J Harmer, R M Sanchez-Panchuelo, R Bowtell, and S T Francis.
- Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.
- NMR Biomed. 2012 May 1; 25 (5): 717-25.
AbstractThe increased blood oxygenation level-dependent contrast-to-noise ratio at ultrahigh field (7 T) has been exploited in a comparison of the spatial location and strength of activation in high-resolution (1.5 mm isotropic) gradient echo (GE) and spin echo (SE), echo planar imaging data acquired during the execution of a simple motor task in five subjects. SE data were acquired at six echo times from 30 to 55 ms. Excellent fat suppression was achieved in the SE echo planar images using slice-selective gradient reversal. Threshold-free cluster enhancement was used to define regions of interest (ROIs) containing voxels showing significant stimulus-locked signal changes from the GE and average SE data. These were used to compare the signal changes and spatial locations of activated regions in SE and GE data. T(2) and T(2)* values were measured, with means of 48.3 ± 1.1 ms and 36.5 ± 3.4 ms in the SE ROI. In addition, we identified a dark band in SE images of the motor cortex corresponding to a region in which T(2) and T(2)* were significantly lower than in the surrounding grey matter. The fractional SE signal change in the ROI was found to vary linearly as a function of TE, with a slope that was dependent on the particular ROI assessed: the mean ΔR(2) value was found to be 0.85 ± 0.11 s(-1) for the SE ROI and -0.37 ± 0.05 s(-1) for the GE ROI. The fractional signal change relative to the shortest TE revealed that the largest signal change occurred at a TE of 45 ms outside of the dark band. At this TE, the ratio of the fractional signal change in GE and SE data was found to be 0.48 ± 0.05. Phase maps produced from high-resolution GE images spanning the right motor cortex were used to identify veins. The GE ROI was found to contain 18% more voxels overlying the venous mask than the SE ROI.Copyright © 2011 John Wiley & Sons, Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.