• Chinese medical journal · Jan 2014

    Comparison of result judgment algorithm of test for interfering factors in the bacterial endotoxins test among Chinese, Japanese, European, American, and Indian pharmacopeias.

    • Yusheng Pei, Tong Cai, Hua Gao, Dejiang Tan, Yuchen Zhang, and Guolai Zhang.
    • National Institute for Food and Drug Control, Beijing 100050, China.
    • Chin. Med. J. 2014 Jan 1; 127 (15): 278427882784-8.

    BackgroundThe bacterial endotoxins test (BET) is a method used to detect or quantify endotoxins (lipo-polysaccharide, LPS) and is widely used in the quality control of parenteral medicines/vaccines and clinical dialysis fluid. It is also used in the diagnosis of endotoxemia and in detection of environment air quality control. Although BET has been adopted by most pharmacopoeias, result judgment algorithms (RJAs) of the test for interfering factors in the BET still differ between certain pharmacopoeias. We have evaluated RJAs of the test for interfering factors for the revision of BET described in the Chinese Pharmacopoeia 2010 (CHP2010).MethodsOriginal data from 1 748 samples were judged by RJAs of the Chinese Pharmacopoeia 2010, the Japanese Pharmacopoeia 2011 (JP2011), the European Pharmacopoeia 7.0 (EP7.0), the United States Pharmacopoeia 36 (USP36), and the Indian Pharmacopoeia 2010 (IP2010), respectively. A SAS software package was used in the statistical analysis.ResultsThe results using CHP2010 and USP36, JP2011, EP7.0, and IP2010 had no significant difference (P = 0.7740). The results using CHP2010 of 1 748 samples showed that 132 samples (7.6%) required an additional step; nevertheless there was no such requirement when using the other pharmacopeias. The kappa value of two RJAs (CHP2010 and EP7.0) was 0.6900 (0.6297-0.7504) indicating that the CHP2010 and other pharmacopoeias have good consistency.ConclusionsThe results using CHP2010 and USP36, JP2011, EP7.0, and IP2010 have different characteristics. CHP2010 method shows a good performance in Specificity, mistake diagnostic rate, agreement rate, predictive value for suspicious rate, and predictive value for passed rate. The CHP2010 method only had disadvantages in sensitivity compared with other pharmacopeias. We suggest that the Chinese pharmacopoeia interference test be revised in accordance with the USP36, JP2011, EP7.0, and IP2010 judgment model.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…