-
Comparative Study
Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: validity of a third-generation device.
- B C Su, Y F Tsai, C Y Chen, H P Yu, M W Yang, W C Lee, and C C Lin.
- Department of Anesthesia, Chang Gung Memorial Hospital-Linkou, and College of Medicine, Chang Gung University, Kwei-Shan Taoyuan, Taiwan.
- Transplant. Proc. 2012 Mar 1;44(2):424-8.
BackgroundHemodynamic monitoring is essential to a successful liver transplantation procedure. FloTrac, a hemodynamic monitor that uses arterial-waveform-based pulse contour analysis for cardiac output (CO) measurement, has proven useful in many clinical settings. One of the primary foci of FloTrac's recent third-generation software upgrade was improving its accuracy in low systemic vascular resistance status. We evaluated the accuracy of the upgraded FloTrac monitor during liver transplantation.Materials And MethodsTwenty-eight patients undergoing liver transplantation were enrolled in the study. Two sets of CO were measured with a radial arterial line connected to a FloTrac monitor (COFT) and a pulmonary artery catheter connected to a continuous cardiac output Vigilence monitor (COPAC). Simultaneous CO measurement was performed and recorded every 5 minutes throughout the surgery. Bland-Altman analysis was used to estimate the accuracy. The comparative method and reference method were considered interchangeable if the limits of agreement did not exceed a threshold set a priori at the greater of ±1 L/min, or a percentage error of lesser than 30%.ResultsIn all, 3234 paired data were collected. The bias was -0.8 L/min and the limits of agreements were -5.6 to 4.0 L/min. Percentage error was 75%. Regression analysis of the systemic vascular resistance index (SVRI) and the bias between COPAC and COFT showed that the bias was inversely related to the SVRI [r2=0.49; P<.001, y=-32.1983+9.9978 Log(x)].ConclusionsDespite a software upgrade, the effectiveness of the FloTrac artery-derived cardiac output monitor for CO measurement during liver transplantation remains limited.Copyright © 2012 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.