• Transplant. Proc. · Mar 2012

    Comparative Study

    Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: validity of a third-generation device.

    • B C Su, Y F Tsai, C Y Chen, H P Yu, M W Yang, W C Lee, and C C Lin.
    • Department of Anesthesia, Chang Gung Memorial Hospital-Linkou, and College of Medicine, Chang Gung University, Kwei-Shan Taoyuan, Taiwan.
    • Transplant. Proc. 2012 Mar 1;44(2):424-8.

    BackgroundHemodynamic monitoring is essential to a successful liver transplantation procedure. FloTrac, a hemodynamic monitor that uses arterial-waveform-based pulse contour analysis for cardiac output (CO) measurement, has proven useful in many clinical settings. One of the primary foci of FloTrac's recent third-generation software upgrade was improving its accuracy in low systemic vascular resistance status. We evaluated the accuracy of the upgraded FloTrac monitor during liver transplantation.Materials And MethodsTwenty-eight patients undergoing liver transplantation were enrolled in the study. Two sets of CO were measured with a radial arterial line connected to a FloTrac monitor (COFT) and a pulmonary artery catheter connected to a continuous cardiac output Vigilence monitor (COPAC). Simultaneous CO measurement was performed and recorded every 5 minutes throughout the surgery. Bland-Altman analysis was used to estimate the accuracy. The comparative method and reference method were considered interchangeable if the limits of agreement did not exceed a threshold set a priori at the greater of ±1 L/min, or a percentage error of lesser than 30%.ResultsIn all, 3234 paired data were collected. The bias was -0.8 L/min and the limits of agreements were -5.6 to 4.0 L/min. Percentage error was 75%. Regression analysis of the systemic vascular resistance index (SVRI) and the bias between COPAC and COFT showed that the bias was inversely related to the SVRI [r2=0.49; P<.001, y=-32.1983+9.9978 Log(x)].ConclusionsDespite a software upgrade, the effectiveness of the FloTrac artery-derived cardiac output monitor for CO measurement during liver transplantation remains limited.Copyright © 2012 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.