-
Randomized Controlled Trial Comparative Study Clinical Trial
Epidural block for obstetrics: comparison of bolus injection of local anesthetic with gravity flow technique.
- S Cohen and D Amar.
- Department of Anesthesiology, Robert Wood Johnson Medical School, New Brunswick, NJ 08903, USA.
- J Clin Anesth. 1997 Dec 1;9(8):623-8.
Study ObjectiveTo test the hypothesis that slow administration of local anesthetic into the epidural space by gravity flow reduces the incidence of signs and symptoms of unintended injection.DesignProspective, randomized study.SettingTeaching hospital.Patients600 ASA physical status l and II parturients scheduled for labor and delivery or elective cesarean section.InterventionsAfter identification of the epidural space with pulsations of an air-fluid column, parturients for vaginal delivery (n = 380) were randomized to receive a test dose of 3 ml 3% 2-chloroprocaine with epinephrine 20 micrograms, two doses of 7 ml bupivacaine 0.03% with sufentanil 1 microgram/ml and epinephrine 2 micrograms/ml by either gravity flow (Group 1) given over 30 seconds or by bolus injection (Group 2) given over 5 seconds through the epidural needle; parturients for Cesarean delivery (n = 220) were randomized to receive a test dose and two doses of 6 ml lidocaine 2% with sufentanil 1 microgram/ml and epinephrine 2 micrograms/ml by either gravity flow or by bolus injection through the epidural needle. Changes in maternal heart rate (HR) and blood pressure, signs of intravascular injection, and adverse effects of epidural bupivacaine-sufentanil were recorded after each dose.Measurements And Main ResultsGravity flow administration (Group 1) was associated with a smaller increase in mean maternal HR (p < 0.001), less hypotension (p < 0.01), sedation (p < 0.01), nausea (p = 0.01), and segmental spread (p < 0.0001) than were corresponding doses given by traditional bolus injection (Group 1) for vaginal or Cesarean deliveries. The incidence of systemic toxicity was zero of 300 (0%) with gravity flow and 4 of 300 (1.3%) by bolus injection, p = 0.12, Fisher's exact test. No patient in either group had an accidental intrathecal injection.ConclusionGravity flow administration of local anesthetic-opioid solution during epidural block for obstetrics was associated with fewer signs of systemic drug absorption and cardiovascular perturbations than was the traditional bolus injection. This study supports the current opinion that slow administration of local anesthetic during epidural block contributes to fewer adverse events.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.