• NeuroImage · Oct 2010

    Rapid 3D radial multi-echo functional magnetic resonance imaging.

    • Gregory R Lee, Mark A Griswold, and Jean A Tkach.
    • Department of Radiology, School of Medicine, Case Western Reserve University/University Hospitals Case Medical Center, Cleveland, Ohio 44106, USA.
    • Neuroimage. 2010 Oct 1;52(4):1428-43.

    AbstractFunctional magnetic resonance imaging with readouts at multiple echo times is useful for optimizing sensitivity across a range of tissue T2* values as well as for quantifying T2*. With single-shot acquisitions, both the minimum TE value and the number of TEs which it is possible to collect within a single TR are limited by the long echo-planar imaging readout duration (20-40 ms). In the present work, a multi-shot 3D radial acquisition which allows rapid whole-brain imaging at a range of echo times is proposed. The proposed 3D k-space coverage is implemented via a series of rotations of a single 2D interleaf. Data can be reconstructed at a variety of temporal resolutions from a single dataset, allowing for a flexible tradeoff between temporal resolution and BOLD contrast to noise ratio. It is demonstrated that whole-brain images at 5 echo times (TEs from 10 to 46 ms) can be acquired at a temporal rate as rapid as 400 ms/volume (3.75 mm isotropic resolution). Activation maps for a simultaneous motor/visual task consistent across multiple acceleration factors are obtained. Weighted combination of the echoes results in Z-scores that are significantly (p=0.016) higher than those resulting from any of the individual echo time images.Copyright 2010 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.