• Resp Care · Aug 2012

    Comparative Study

    Comparison of maximal inspiratory pressure, tracheal airway occlusion pressure, and its ratio in the prediction of weaning outcome: impact of the use of a digital vacuometer and the unidirectional valve.

    • Leonardo Cordeiro de Souza, Cyro Teixeira da Silva, Jorge Reis Almeida, and Jocemir Ronaldo Lugon.
    • Department of Medicine, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil. leonardo.uti@gmail.com
    • Resp Care. 2012 Aug 1;57(8):1285-90.

    ObjectiveTo investigate the predictive value of the maximal inspiratory pressure obtained by a digital vacuometer using a unidirectional valve (P(ImaxUV)) as to weaning outcome, and to compare its performance with the respiratory drive using airway occlusion pressure at 0.1 second (P(0.1)), and P(0.1)/P(ImaxUV).MethodsPatients on mechanical ventilation for > 24 hours who fulfilled the weaning criteria were prospectively enrolled. Measurements of P(ImaxUV) and P(0.1) were accomplished with a digital vacuometer with a unidirectional valve that allows only exhalation. Measured values were electronically recorded and stored on the digital vacuometer measurement device. Cutoff points for the used parameters were: absolute values of P(ImaxUV) > 30 cm H(2)O, P(0.1) < 2.3 cm H(2)O, and P(0.1)/P(ImaxUV) < 0.10. Receiver operating characteristic curves were calculated to compare the predictive values of the indexes.ResultsOne hundred three subjects completed the test. The areas under the receiver operating characteristic curve were 0.79 ± 0.04, 0.65 ± 0.05, and 0.74 ± 0.04 for P(ImaxUV), P(0.1), and P(0.1)/P(ImaxUV), respectively. The area under the receiver operating characteristic curve for P(ImaxUV) was higher than for P(0.1) and P(0.1)/P(ImaxUV), but statistical significance was only found against P(0.1) (P = .007).ConclusionsEvery studied index had only a modest performance regarding prediction of weaning outcome. Of note, P(ImaxUV) values obtained by digital technology using a unidirectional valve performed better than historically reported using a conventional techniques, surpassing P(0.1) and P(0.1)/P(ImaxUV) in this regard.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…