- Leonardo Cordeiro de Souza, Cyro Teixeira da Silva, Jorge Reis Almeida, and Jocemir Ronaldo Lugon.
- Department of Medicine, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil. leonardo.uti@gmail.com
- Resp Care. 2012 Aug 1;57(8):1285-90.
ObjectiveTo investigate the predictive value of the maximal inspiratory pressure obtained by a digital vacuometer using a unidirectional valve (P(ImaxUV)) as to weaning outcome, and to compare its performance with the respiratory drive using airway occlusion pressure at 0.1 second (P(0.1)), and P(0.1)/P(ImaxUV).MethodsPatients on mechanical ventilation for > 24 hours who fulfilled the weaning criteria were prospectively enrolled. Measurements of P(ImaxUV) and P(0.1) were accomplished with a digital vacuometer with a unidirectional valve that allows only exhalation. Measured values were electronically recorded and stored on the digital vacuometer measurement device. Cutoff points for the used parameters were: absolute values of P(ImaxUV) > 30 cm H(2)O, P(0.1) < 2.3 cm H(2)O, and P(0.1)/P(ImaxUV) < 0.10. Receiver operating characteristic curves were calculated to compare the predictive values of the indexes.ResultsOne hundred three subjects completed the test. The areas under the receiver operating characteristic curve were 0.79 ± 0.04, 0.65 ± 0.05, and 0.74 ± 0.04 for P(ImaxUV), P(0.1), and P(0.1)/P(ImaxUV), respectively. The area under the receiver operating characteristic curve for P(ImaxUV) was higher than for P(0.1) and P(0.1)/P(ImaxUV), but statistical significance was only found against P(0.1) (P = .007).ConclusionsEvery studied index had only a modest performance regarding prediction of weaning outcome. Of note, P(ImaxUV) values obtained by digital technology using a unidirectional valve performed better than historically reported using a conventional techniques, surpassing P(0.1) and P(0.1)/P(ImaxUV) in this regard.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.