-
- Sarah A Spinler, Edith A Nutescu, Maureen A Smythe, and Ann K Wittkowsky.
- Cardiovascular Division, Department of Medicine, Philadelphia College of Pharmacy, University of Pennsylvania, Philadelphia, PA 19104-4495, USA. s.spinle@usip.edu
- Ann Pharmacother. 2005 Jun 1;39(6):1049-55.
ObjectiveTo review the availability, mechanisms, limitations, and clinical application of point-of-care (POC) devices used in the management of warfarin and parenteral direct thrombin inhibitors.Data SourcesScientific articles were identified through a MEDLINE search (1966-August 2004), manufacturer Web sites, additional references listed in articles and Web sites, and abstracts from scientific meetings.Study Selection And Data ExtractionEnglish-language literature from clinical trials was reviewed to evaluate the accuracy, reliability, and clinical application of POC monitoring devices.Data SynthesisThe prothrombin time expressed as the international normalized ratio (PT-INR) is a well-established test for monitoring warfarin anticoagulation. Multiple devices are available for POC testing. Because there is no universally accepted standard, the performance of each device is typically tested against a standard test performed in a reference laboratory. Performance of currently available devices, as measured by correlations to a standard reference laboratory PT-INR, may be considered very good and acceptable for use in patient care. Utilization of patient self-testing and patient self-monitoring of warfarin anticoagulation using POC devices is increasing. Parenteral direct thrombin inhibitors are typically monitored using a standard laboratory activated partial thromboplastin time. Some research has shown that POC monitoring of direct thrombin inhibitors using the ecarin clotting time is helpful for patients undergoing cardiopulmonary bypass surgery, although that test is not readily available.ConclusionsPOC testing for anticoagulation therapy has been available for >20 years. Multiple POC devices are available to monitor warfarin. There is some variability in results between devices and between reagents used in the same device. Despite these limitations, POC monitoring of warfarin via the PT-INR is an integral part of clinical practice. Additional research evaluating POC monitoring of direct thrombin inhibitors is necessary.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.