• NMR in biomedicine · May 2012

    The importance of axonal undulation in diffusion MR measurements: a Monte Carlo simulation study.

    • Markus Nilsson, Jimmy Lätt, Freddy Ståhlberg, Danielle van Westen, and Håkan Hagslätt.
    • Department of Medical Radiation Physics, Lund University, Lund, Sweden. markus.nilsson@med.lu.se
    • NMR Biomed. 2012 May 1;25(5):795-805.

    AbstractMany axons follow wave-like undulating courses. This is a general feature of extracranial nerve segments, but is also found in some intracranial nervous tissue. The importance of axonal undulation has previously been considered, for example, in the context of biomechanics, where it has been shown that posture affects undulation properties. However, the importance of axonal undulation in the context of diffusion MR measurements has not been investigated. Using an analytical model and Monte Carlo simulations of water diffusion, this study compared undulating and straight axons in terms of diffusion propagators, diffusion-weighted signal intensities and parameters derived from diffusion tensor imaging, such as the mean diffusivity (MD), the eigenvalues and the fractional anisotropy (FA). All parameters were strongly affected by the presence of undulation. The diffusivity perpendicular to the undulating axons increased with the undulation amplitude, thus resembling that of straight axons with larger diameters. Consequently, models assuming straight axons for the estimation of the axon diameter from diffusion MR measurements might overestimate the diameter if undulation is present. FA decreased from approximately 0.7 to 0.5 when axonal undulation was introduced into the simulation model structure. Our results indicate that axonal undulation may play a role in diffusion measurements when investigating, for example, the optic and sciatic nerves and the spinal cord. The simulations also demonstrate that the stretching or compression of neuronal tissue comprising undulating axons alters the observed water diffusivity, suggesting that posture may be of importance for the outcome of diffusion MRI measurements.Copyright © 2011 John Wiley & Sons, Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…