• J Trauma Acute Care Surg · Feb 2016

    Prehospital airway technique does not influence incidence of ventilator-associated pneumonia in trauma patients.

    • Michael Thomas Steuerwald, Bryce R H Robinson, Dennis J Hanseman, Amy Makley, and Timothy A Pritts.
    • From the Departments of Emergency Medicine (M.T.S.) and Surgery (B.R.H.R., D.J.H., A.M., T.A.P.) and the Institute for Military Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio.
    • J Trauma Acute Care Surg. 2016 Feb 1; 80 (2): 283-8.

    BackgroundThe relationship between the prehospital airway device used and later development of ventilator-associated pneumonia (VAP) is unknown. We sought to determine if the prehospital airway device choice is associated with an increased risk of VAP in risk-adjusted critically injured patients.MethodsWe performed a retrospective analysis of all trauma patients requiring definitive airway placement before intensive care unit admission at a Level I trauma center from 2008 to 2012. Prehospital airway management strategies were classified as extraglottic device placement, endotracheal intubation, bag-valve mask ventilation (BVM), or lack of a prehospital airway with subsequent intubation at the trauma center. Patients were excluded if they were hospital transfers, were dead on arrival, died in the emergency department, or did not require at least 48 hours of mechanical ventilation. The primary end point was the development of VAP as determined by institutional guidelines for diagnosis. Logistic regression was used to determine risk factors for VAP.ResultsA total of 317 patients met inclusion criteria. The median age was 37 years (interquartile range, 25-51 years), 75% were male, 78% sustained a blunt injury, and the median Injury Severity Score (ISS) was 29 (interquartile range, 21-34). Ninety-seven patients (30.6%) developed VAP. Prehospital airway strategies were as follows: 17 (5.4%) had extraglottic device placement, 28 (8.8%) had BVM, 84 (26.5%) had endotracheal intubation, and 188 (59.3%) had no prehospital airway placement and were intubated after arrival. The type of prehospital airway was not statistically significant in terms of VAP development (range, 26.1-42.9%; p = 0.15). The only statistically significant predictor of VAP was length of mechanical ventilation (univariate: odds ratio, 1.14; 95% confidence interval, 1.10-1.18; p ≤ 0.01; multivariate: odds ratio, 1.15; 95% confidence interval, 1.10-1.20; p ≤ 0.01).ConclusionOur data suggest that the prehospital airway device used was not associated with the development of VAP.Level Of EvidenceTherapeutic study, level IV; epidemiologic study, level III.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.