• Pol. Arch. Med. Wewn. · Jun 2020

    The clinical value of routine analysis of cardiac implantable electronic devices after death in the tertiary cardiovascular centre.

    • Mateusz Tajstra, Maciej Dyrbuś, Jerzy Nożyński, Jacek Niedziela, Elżbieta Gadula-Gacek, Ewa Zembala-Nożyńska, Ewa Trejnowska, Agata Stanek-Widera, Dariusz Lange, Piotr Knapik, and Mariusz Gąsior.
    • 3rd Department of Cardiology, School of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland. mateusztajstra@wp.pl
    • Pol. Arch. Med. Wewn. 2020 Jun 25; 130 (6): 492-500.

    IntroductionThe postmortem interrogation of cardiac implantable electronic devices (CIEDs) has not been regularly practiced yet. We presumed that it can provide data not only on the mechanism of the patient's death but also on possible device malfunctions contributing to its occurrence.ObjectivesThe study aimed to determine the usefulness of the explantation and interrogation of CIEDs after the patient's death in routine clinical practice, when combined with autopsy findings and clinical follow‑up starting from the time after device implantation.Patients And MethodsBetween August 24, 2008 and August 30, 2018, all patients who underwent autopsy in the tertiary cardiovascular center or partner facilities had the device explanted and interrogated by the qualified electrophysiologist. Clinical characteristics obtained at the time of device implantation and patients' death were obtained from medical records. Device interrogation results were then combined with autopsy report and clinical data.ResultsOut of 1200 autopsied patients, the device was removed and analyzed in 61 individuals. Clinical characteristics from the time of implantation and patients' death were available in 53 (86.7%) and 49 (80.3%) patients, respectively. Device‑related concerns, undetected during patients' hospital stay, were noted in 6 cases (6.1%) and included 3 programming and 3 hardware issues.ConclusionsTo our knowledge, this is the first study to date to combine the clinical follow‑up of patients before death and on admission at the end of life, autopsy results, and postmortem CIED interrogation. Having implemented the device interrogation, we found 6 CIED‑related events potentially associated with patients' death, which were not detected before its occurrence.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…